some updates to transfer step forms
1 parent 90171d1 commit f3c8046

File tree

4 files changed

+28
-14
lines changed

4 files changed

+28
-14
lines changed

docs/protocol-designer/docs/create-protocol/modules-fixtures.md

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -31,4 +31,4 @@ Click **Deck hardware** in the left sidebar, then click :material-plus-circle: o
3131
| Waste Chute | <ul><li>Only 1 waste chute</li><li>Slot D3</li></ul> | Not compatible |
3232
| Staging area | <ul><li>Up to 4 staging areas</li><li>Slots A4-D4</li></ul> | Not compatible |
3333

34-
You can create additional space on the Flex deck by adding as many as four staging areas, creating slots A4-D4.
34+
You can create additional space on the Flex deck by adding as many as four staging areas in slots A4-D4.
107 KB
Loading

docs/protocol-designer/docs/steps/mix.md

Lines changed: 6 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -4,7 +4,12 @@ title: "Protocol Designer: Mix steps"
44

55
In a mix step, the robot mixes liquid by repeatedly aspirating and dispensing. Mixing occurs in each well you select, one after the other, without moving any liquid between wells.
66

7-
You can customize settings for your mix step in a two-part form. Just like in a transfer step, start by selecting a pipette, tip rack, and labware. You can customize volume per well and the number of times the robot will mix. Choose tip management settings, or how often the robot will select a new tip, and a tip drop location before clicking **Continue**.
7+
You can customize settings for your mix step in a four-part form. Just like in a transfer step, start by selecting a pipette, tip rack, and labware. You can customize volume per well and the number of times the robot will mix. In the following forms, you can customize:
8+
9+
- whether to use liquid class settings.
10+
- aspirate and dispense settings like flow rate.
11+
- tip management settings, including how often the robot will select a new tip and which tip should be picked up.
12+
- the tip drop location.
813

914
<figure class="screenshot" markdown>
1015
![Mix step](../images/mix_step.png)

docs/protocol-designer/docs/steps/transfer.md

Lines changed: 21 additions & 12 deletions
Original file line numberDiff line numberDiff line change
@@ -6,7 +6,7 @@ Your protocol timeline includes steps the robot will peform in your protocol. To
66

77
## The basics
88

9-
Transfer steps move liquid from one well or group of wells to another. Adding a transfer step opens a three-part form. In the first, select basic settings for your liquid transfer:
9+
Transfer steps move liquid from one well or group of wells to another. Adding a transfer step opens a four-part form. In the first, select basic settings for your liquid transfer:
1010

1111
* The pipette to perform the transfer and the tip rack it will use.
1212
* Source and destination labware, including wells.
@@ -17,23 +17,23 @@ Click **Choose wells**, and then click and drag to select source and destination
1717

1818
| **Pipette Path** | **Well Ratio** | **Description** {style="width: 25%;"}| **Tip Handling** |
1919
| ---------------- | -------------- | --------------- | ---------------- |
20-
| Single path | N to N | <ul><li>Aspirates enough liquid for a single transfer and repeats</li></ul> | Select a new tip: <ul><li>Before every aspirate</li><li>Once at the start of the step</li><li>Per source well</li><li>Never</li></ul> |
21-
| Consolidate path | Many-to-1 | <ul><li>Multi-aspirate</li><li>Aspirates from multiple wells for a single dispense</li></ul> | Select a new tip: <ul><li>Before every aspirate</li><li>Once at the start of the step</li><li>Never</li></ul> |
22-
| Distribute path | 1-to-many | <ul><li>Multi-dispense</li><li>Aspirates enough volume from 1 well for multiple dispenses</li></ul> | Select a new tip: <ul><li>Before every aspirate</li><li>Once at the start of the step</li><li>Never</li></ul> |
20+
| Single path | N to N | <ul><li>Aspirates enough liquid for a single transfer and repeats</li></ul> | Select a new tip: <ul><li>Always</li><li>Never</li><li>Once</li><li>Per source</li></ul> |
21+
| Consolidate path | Many-to-1 | <ul><li>Multi-aspirate</li><li>Aspirates from multiple wells for a single dispense</li></ul> | Select a new tip: <ul><li>Always</li><li>Never</li><li>Once</li></ul> |
22+
| Distribute path | 1-to-many | <ul><li>Multi-dispense</li><li>Aspirates enough volume from 1 well for multiple dispenses</li></ul> | Select a new tip: <ul><li>Always</li><li>Never</li><li>Once</li></ul> |
2323

2424
Lids on labware block transfer steps in your protocol. If every piece of labware on the deck includes a lid, only move, pause, and relevant module steps will be available. Use a move step to remove lids, then add a transfer step.
2525

2626
## Tip management
2727

28-
Customizing tip management in your transfer steps can prevent contamination or reduce tip use in a protocol. Choose how often the robot selects a new tip:
28+
Customizing tip management in your transfer steps can prevent contamination or reduce tip use in a protocol. First, choose how often the robot selects a new tip:
2929

30-
* **Before every aspirate**: selects a new tip before every aspirate in a transfer step.
31-
* **Once at the start of the step**: selects a new tip once at the beginning of the entire transfer step.
30+
* **Always**: selects a new tip before every aspirate in a transfer step.
31+
* **Once**: selects a new tip once at the beginning of the entire transfer step.
3232
* **Never**: reuses the tip used in the previous step.
33-
* **Per source well**: selects a new tip for each source well, including the first. Not compatible with a consolidate or distribute path.
34-
* **Per destination well**: selects a new tip for each destination well, including the first. Not compatible with a consolidate or distribute path.
33+
* **Per source**: selects a new tip for each source well, including the first. Not compatible with a consolidate or distribute path.
34+
* **Per destination**: selects a new tip for each destination well, including the first. Not compatible with a consolidate or distribute path.
3535

36-
Consolidate and distribute paths use a cycle of aspiration and dispensing to combine liquid in source or destination wells. When you choose "before every aspirate" for a consolidate or dispense path, the robot selects a new tip before the first aspirate of the cycle:
36+
Consolidate and distribute paths use a cycle of aspiration and dispensing to combine liquid in source or destination wells. When you choose "always" for a consolidate or dispense path, the robot selects a new tip before the first aspirate of the cycle:
3737

3838
* Consolidate cycle: aspirate, aspirate, dispense.
3939
* Distribute cycle: aspirate, dispense, dispense.
@@ -45,10 +45,19 @@ If you choose an incompatible well ratio or an empty source well, Protocol Desig
4545
<figcaption>Incompatible well ratio in a transfer step.</figcaption>
4646
</figure>
4747

48-
Choose a tip drop location to dispose of used tips before clicking **Continue**. Options include fixtures like the trash bin and waste chute, if used in your protocol, or to return tips to the tip rack.
48+
Next, choose a tip drop location to dispose of used tips before clicking **Continue**. Options include fixtures like the trash bin and waste chute, if used in your protocol, or to return tips to the tip rack.
4949

5050
!!! Note
51-
If you select **Tip rack** as the tip drop location, the pipette will return tips to their original position in the tip rack. You won't be able to pick up these tips again in the same protocol.
51+
If you select **Tip rack** as the tip drop location, the pipette will return tips to their original position in the tip rack. You won't be able to pick up these tips again in the same protocol.
52+
53+
You can customize tip tracking settings in your Protocol Designer protocols. When you select automatic tip tracking, Protocol Designer keeps track of which tips have been picked up and used, starting with the tip in position A1 of the tip rack you chose for the transfer.
54+
55+
Click **manual tip tracking** to choose the tips the pipette will use in your transfer step. Tips are labeled as new, used, or selected for your transfer. Protocol Designer also shows you tips that have been discarded and are missing from the tip rack, or tips that are inaccessible, or unable to be picked up by, your chosen pipette.
56+
57+
<figure class="screenshot" markdown>
58+
![Manual tip selection](../images/tip_selection.png)
59+
<figcaption>Click to select tips for your transfer step.</figcaption>
60+
</figure>
5261

5362
In the second form, choose whether to use liquid class settings in the transfer. You can choose from three Opentrons-verified liquid classes: for an aqueous, viscous, or volatile liquid. Applying a liquid class changes the transfer step's pipetting settings, so Protocol Designer will ask you each time.
5463

0 commit comments

Comments
 (0)